Marfork Coal Company Petition for Safety Standards Modification
Summary
The Mine Safety and Health Administration published a petition filed by Marfork Coal Company seeking modification of existing mandatory safety standards. The petition is open for public comment until May 4, 2026. This is a routine administrative filing under MSHA's petition process.
What changed
Marfork Coal Company has filed a petition with MSHA requesting modification of mandatory safety standards applicable to coal mining operations. The petition was published on April 3, 2026, and is currently open for public comment through May 4, 2026. No specific details about the safety standard being modified are provided in the notice.\n\nMining industry stakeholders and interested parties should review the petition and submit comments via regulations.gov or the Federal Register portal by the May 4, 2026 deadline. MSHA will evaluate the petition based on whether the proposed alternative provides equivalent protection to miners.
What to do next
- Review the petition details on regulations.gov
- Submit public comments by May 4, 2026 if affected by the proposed modification
- Monitor MSHA decisions on the petition
Source document (simplified)
Legal Status This site displays a prototype of a “Web 2.0” version of the daily
Federal Register. It is not an official legal edition of the Federal
Register, and does not replace the official print version or the official
electronic version on GPO’s govinfo.gov.
The documents posted on this site are XML renditions of published Federal
Register documents. Each document posted on the site includes a link to the
corresponding official PDF file on govinfo.gov. This prototype edition of the
daily Federal Register on FederalRegister.gov will remain an unofficial
informational resource until the Administrative Committee of the Federal
Register (ACFR) issues a regulation granting it official legal status.
For complete information about, and access to, our official publications
and services, go to About the Federal Register on NARA's archives.gov.
The OFR/GPO partnership is committed to presenting accurate and reliable
regulatory information on FederalRegister.gov with the objective of
establishing the XML-based Federal Register as an ACFR-sanctioned
publication in the future. While every effort has been made to ensure that
the material on FederalRegister.gov is accurately displayed, consistent with
the official SGML-based PDF version on govinfo.gov, those relying on it for
legal research should verify their results against an official edition of
the Federal Register. Until the ACFR grants it official status, the XML
rendition of the daily Federal Register on FederalRegister.gov does not
provide legal notice to the public or judicial notice to the courts.
Legal Status
Notice
Petition for Modification of Application of Existing Mandatory Safety Standards
A Notice by the Mine Safety and Health Administration on 04/03/2026
- 1.
1.
This document has a comment period that ends in 31 days.
(05/04/2026) View Comment Instructions
Thank you for taking the time to create a comment. Your input is important.
Once you have filled in the required fields below you can preview and/or submit your comment to the Labor Department for review. All comments are considered public and will be posted online once the Labor Department has reviewed them.
You can view alternative ways to comment or you may also comment via Regulations.gov at /documents/2026/04/03/2026-06512/petition-for-modification-of-application-of-existing-mandatory-safety-standards.
It appears that you have attempted to comment on this document before
so we've restored your progress.
Start over.
1.
2. Comment * What is your comment about? Upload File(s) Note: You can attach your comment as a file and/or attach supporting
documents to your comment. Attachment Requirements.
Email this will NOT be posted on regulations.gov
Opt to receive email confirmation of submission and tracking number? Tell us about yourself! I am... * An Individual An Organization Anonymous First Name * Last Name * City Region State Alabama Alaska American Samoa Arizona Arkansas California Colorado Connecticut Delaware District of Columbia Florida Georgia Guam Hawaii Idaho Illinois Indiana Iowa Kansas Kentucky Louisiana Maine Maryland Massachusetts Michigan Minnesota Mississippi Missouri Montana Nebraska Nevada New Hampshire New Jersey New Mexico New York North Carolina North Dakota Ohio Oklahoma Oregon Pennsylvania Puerto Rico Rhode Island South Carolina South Dakota Tennessee Texas Utah Vermont Virgin Islands Virginia Washington West Virginia Wisconsin Wyoming Zip Country Afghanistan Åland Islands Albania Algeria American Samoa Andorra Angola Anguilla Antarctica Antigua and Barbuda Argentina Armenia Aruba Australia Austria Azerbaijan Bahamas Bahrain Bangladesh Barbados Belarus Belgium Belize Benin Bermuda Bhutan Bolivia, Plurinational State of Bonaire, Sint Eustatius and Saba Bosnia and Herzegovina Botswana Bouvet Island Brazil British Indian Ocean Territory Brunei Darussalam Bulgaria Burkina Faso Burundi Cambodia Cameroon Canada Cape Verde Cayman Islands Central African Republic Chad Chile China Christmas Island Cocos (Keeling) Islands Colombia Comoros Congo Congo, the Democratic Republic of the Cook Islands Costa Rica Côte d'Ivoire Croatia Cuba Curaçao Cyprus Czech Republic Denmark Djibouti Dominica Dominican Republic Ecuador Egypt El Salvador Equatorial Guinea Eritrea Estonia Ethiopia Falkland Islands (Malvinas) Faroe Islands Fiji Finland France French Guiana French Polynesia French Southern Territories Gabon Gambia Georgia Germany Ghana Gibraltar Greece Greenland Grenada Guadeloupe Guam Guatemala Guernsey Guinea Guinea-Bissau Guyana Haiti Heard Island and McDonald Islands Holy See (Vatican City State) Honduras Hong Kong Hungary Iceland India Indonesia Iran, Islamic Republic of Iraq Ireland Isle of Man Israel Italy Jamaica Japan Jersey Jordan Kazakhstan Kenya Kiribati Korea, Democratic People's Republic of Korea, Republic of Kuwait Kyrgyzstan Lao People's Democratic Republic Latvia Lebanon Lesotho Liberia Libya Liechtenstein Lithuania Luxembourg Macao Macedonia, the Former Yugoslav Republic of Madagascar Malawi Malaysia Maldives Mali Malta Marshall Islands Martinique Mauritania Mauritius Mayotte Mexico Micronesia, Federated States of Moldova, Republic of Monaco Mongolia Montenegro Montserrat Morocco Mozambique Myanmar Namibia Nauru Nepal Netherlands New Caledonia New Zealand Nicaragua Niger Nigeria Niue Norfolk Island Northern Mariana Islands Norway Oman Pakistan Palau Palestine, State of Panama Papua New Guinea Paraguay Peru Philippines Pitcairn Poland Portugal Puerto Rico Qatar Réunion Romania Russian Federation Rwanda Saint Barthélemy Saint Helena, Ascension and Tristan da Cunha Saint Kitts and Nevis Saint Lucia Saint Martin (French part) Saint Pierre and Miquelon Saint Vincent and the Grenadines Samoa San Marino Sao Tome and Principe Saudi Arabia Senegal Serbia Seychelles Sierra Leone Singapore Sint Maarten (Dutch part) Slovakia Slovenia Solomon Islands Somalia South Africa South Georgia and the South Sandwich Islands South Sudan Spain Sri Lanka Sudan Suriname Svalbard and Jan Mayen Swaziland Sweden Switzerland Syrian Arab Republic Taiwan, Province of China Tajikistan Tanzania, United Republic of Thailand Timor-Leste Togo Tokelau Tonga Trinidad and Tobago Tunisia Turkey Turkmenistan Turks and Caicos Islands Tuvalu Uganda Ukraine United Arab Emirates United Kingdom United States United States Minor Outlying Islands Uruguay Uzbekistan Vanuatu Venezuela, Bolivarian Republic of Viet Nam Virgin Islands, British Virgin Islands, U.S. Wallis and Futuna Western Sahara Yemen Zambia Zimbabwe Phone Organization Type * Company Organization Federal State Local Tribal Regional Foreign U.S. House of Representatives U.S. Senate Organization Name * You are filing a document into an official docket. Any personal
information included in your comment text and/or uploaded
attachment(s) may be publicly viewable on the web. I read and understand the statement above.
- Preview Comment Please review the Regulations.gov privacy notice and user notice.
- Document Details Published Content - Document Details Agencies Department of Labor Mine Safety and Health Administration Document Citation 91 FR 16977 Document Number 2026-06512 Document Type Notice Pages 16977-16979 (3 pages) Publication Date 04/03/2026 Published Content - Document Details
- PDF Official Content
- View printed version (PDF) Official Content
- Document Details Published Content - Document Details Agencies Department of Labor Mine Safety and Health Administration Document Citation 91 FR 16977 Document Number 2026-06512 Document Type Notice Pages 16977-16979 (3 pages) Publication Date 04/03/2026 Published Content - Document Details
- Document Dates Published Content - Document Dates Comments Close 05/04/2026 Dates Text All comments on the petition must be received by MSHA's Office of Standards, Regulations, and Variances on or before May 4, 2026. Published Content - Document Dates
Table of Contents Enhanced Content - Table of Contents This table of contents is a navigational tool, processed from the
headings within the legal text of Federal Register documents.
This repetition of headings to form internal navigation links
has no substantive legal effect.- AGENCY:
- ACTION:
- SUMMARY:
- DATES:
- ADDRESSES:
- FOR FURTHER INFORMATION CONTACT:
- SUPPLEMENTARY INFORMATION:
- I. Background
- II. Petition for Modification Enhanced Content - Table of Contents
Public Comments Enhanced Content - Public Comments Comments are being accepted - View Comment Instructions.
Enhanced Content - Public Comments
- Regulations.gov Data Enhanced Content - Regulations.gov Data Additional information is not currently available for this document.
Enhanced Content - Regulations.gov Data
- Sharing Enhanced Content - Sharing Shorter Document URL https://www.federalregister.gov/d/2026-06512 Email Email this document to a friend Enhanced Content - Sharing
- Print Enhanced Content - Print
- Print this document Enhanced Content - Print
- Other Formats Enhanced Content - Other Formats This document is also available in the following formats:
JSON Normalized attributes and metadata XML Original full text XML MODS Government Publishing Office metadata More information and documentation can be found in our developer tools pages.
Enhanced Content - Other Formats
- Public Inspection Public Inspection This PDF is FR Doc. 2026-06512 as it appeared on Public Inspection on
04/02/2026 at 8:45 am.
It was viewed
6
times while on Public Inspection.
If you are using public inspection listings for legal research, you
should verify the contents of the documents against a final, official
edition of the Federal Register. Only official editions of the
Federal Register provide legal notice of publication to the public and judicial notice
to the courts under 44 U.S.C. 1503 & 1507. Learn more here.
Public Inspection
Published Document: 2026-06512 (91 FR 16977) This document has been published in the Federal Register. Use the PDF linked in the document sidebar for the official electronic format.
Document Headings Document headings vary by document type but may contain
the following:
- the agency or agencies that issued and signed a document
- the number of the CFR title and the number of each part the document amends, proposes to amend, or is directly related to
- the agency docket number / agency internal file number
- the RIN which identifies each regulatory action listed in the Unified Agenda of Federal Regulatory and Deregulatory Actions See the Document Drafting Handbook for more details.
Department of Labor
Mine Safety and Health Administration
AGENCY:
Mine Safety and Health Administration, Labor.
ACTION:
Notice.
SUMMARY:
This notice is a summary of a petition for modification submitted to the Mine Safety and Health Administration (MSHA) by Marfork Coal Company, LLC.
DATES:
All comments on the petition must be received by MSHA's Office of Standards, Regulations, and Variances on or before May 4, 2026.
ADDRESSES:
You may submit comments identified by Docket No. MSHA-2026-0102 by any of the following methods:
Federal eRulemaking Portal: https://www.regulations.gov. Follow the instructions for submitting comments for MSHA-2026-0102.
Fax: 202-693-9441.
Email: petitioncomments@dol.gov.
Regular Mail or Hand Delivery: MSHA, Office of Standards, Regulations, and Variances, Room C3522, 200 Constitution Ave. NW, Washington, DC 20210.
Attention: Jessica D. Senk, Acting Director, Office of Standards, Regulations, and Variances. Individuals may inspect copies of the petition and comments during normal business hours at the address listed above. Before visiting MSHA in person, call 202-693-9440 to make an appointment.
FOR FURTHER INFORMATION CONTACT:
Jessica D. Senk, Office of Standards, Regulations, and Variances at 202-693-9440 (voice), Petitionsformodification@dol.gov (email), or 202-693-9441 (fax). These are not toll-free numbers.
SUPPLEMENTARY INFORMATION:
Section 101(c) of the Federal Mine Safety and Health Act of 1977 and Title 30 of the Code of Federal Regulations (CFR) part 44 govern the application, processing, and disposition of petitions for modification.
I. Background
Section 101(c) of the Federal Mine Safety and Health Act of 1977 (Mine Act) allows the mine operator or representative of miners to file a petition to modify the application of any mandatory safety standard to a coal or other mine if the Secretary of Labor determines that:
An alternative method of achieving the result of such standard exists which will at all times guarantee no less than the same measure of protection afforded the miners of such mine by such standard; or
The application of such standard to such mine will result in a diminution of safety to the miners in such mine.
In addition, sections 44.10 and 44.11 of 30 CFR establish the requirements for filing petitions for modification.
II. Petition for Modification
Docket Number: M-2026-004-C.
Petitioner: Marfork Coal Company, LLC, 500 Cutler Trico Road, Percy, IL 62272.
Mine: Glen Alum Tunnel Mine, MSHA ID No. 46-09375, located in Raleigh County, West Virginia.
Regulation Affected: 30 CFR 75.1002 (a), Permissible electric equipment.
Modification Request: The petitioner requests a modification of the existing standard, 30 CFR 75.1002(a) to permit alternative methods of compliance to permit the use of additional respirable dust protection. Specifically, the petitioner is requesting to permit the use of a 3M Versaflow TR-800-HIK Intrinsically Safe Powered Air Purifying Respirator (PAPR) motor/blower and battery.
The petitioner states that:
(a) The petitioner seeks modification of 30 CFR 75.1002(a), as it pertains to the use of battery-powered respirable protection.
(b) That standard 30 CFR 75.1002(a) provides in relevant part:
Electric equipment must be permissible and maintained in a permissible condition when such equipment is located within 150 feet of pillar workings or longwall faces.
(c) Currently, the petitioner does not use a battery powered respirator unit but would like to add a PAPR to the units available to miners in certain situations.
(d) Currently there are no battery powered respirators that meet applicable MSHA standards for permissibility. Electronic equipment used in underground mines in potentially explosive atmospheres is required to be approved by MSHA per 30 CFR. 3M and other competitor manufacturers do offer alternative products for many other environments and applications.
(e) One of the main benefits of a PAPR is that they provide a constant flow of ( printed page 16978) air inside the headtop or helmet. This constant airflow helps to provide both respiratory protection and comfort in warm working environments.
(f) A strict application of the standard (i.e. —objecting to the use of the requested PAPR) results in a diminution of safety at the mine.
(g) The petitioner is requesting to permit the use of a 3M product, the Versaflow TR-800-HIK Intrinsically Safe Powered Air Purifying Respirator motor/blower and battery.
(h) The Versaflow TR-800-HIK motor/blower and battery qualifies as intrinsically safe in the US, Canada, and any other country accepting IECEx reports. (IECEx is the International Electrotechnical Commissions System for Certification to Standards. Relating to Equipment for Use in Explosive Atmosphere). The TR-800-HIK PAPR has a blower that is UL-certified with an intrinsically safe (IS) rating of Division 1: IS Class I, II, III; Division 1 (includes Division 2) Groups C, D, E, F, G; T4, under the most current standard (UL 60079, 6th Edition, 2013). ATEX-certified with an intrinsically safe (IS) rating of “ia”. The TR-800 is rated and marked with Exia I Ma, Exia IIB T4 Ga, Ex ia IIIC 135 °C Da, −20 °C ≤ Ta ≤ +55 °C, under the current standard (IEC 60079).
(i) The 3M Versaflow TR-800 Intrinsically Safe Powered Air Purifying Respirator is not MSHA approved as permissible and 3M is not pursuing approval to our knowledge.
(j) The standards for approval of these respirators are an acceptable alternative to MSHA's standards and provide an equivalent level of protection.
(k) The petitioner seeks an alternative method to the mandatory safety standard, asserting it will at all times guarantee no less than the same measure of protection afforded the miners under the mandatory standard.
The petitioner proposes the following alternative method:
(a) Affected mine employees must be trained in the proper use and maintenance of the Versaflo TR-800 PAPR in accordance with established manufacturer guidelines. This training shall alert the affected employee that the Versaflo TR-800 PAPR is approved under 30 CFR part 18 and must be de-energized when 1.0 or more percent methane is detected. The training shall also include the proper method to de-energize the PAPR. In addition to manufacturer guidelines, the petitioner will require that mine employees be trained to inspect the units before use to determine if there is any damage to the units that would negatively impact intrinsic safety as well as all stipulations in this petition.
(b) The PAPR, battery pack, and all associated wiring and any connections must be inspected before use to determine if there is any damage to the units that would negatively impact intrinsic safety. If any defects are found, the PAPR must be removed from service.
(c) The operator will maintain a separate logbook for the 3M Versaflo TR-800 PAPR that shall be kept with the equipment, or in a location with other mine record books and shall be made available to MSHA upon request. The equipment shall be examined at least weekly by a qualified person as defined in 30 CFR 75.512-1 and the examination results recorded in the logbook. Since float coal dust is removed by the air filter prior to reaching the motor, the PAPR user shall conduct regular examinations of the filter and perform periodic testing for proper operation of the “high filter load alarm” on the 3M Versaflo TR-800 PAPR.
(d) All 3M Versaflo TR-800 to be used within 150 feet of pillar workings or longwall faces, shall be physically examined prior to initial use and each unit will be assigned a unique identification number. Each unit shall be examined by the person to operate the equipment prior to taking the equipment underground to ensure the equipment is being used according to the original equipment manufacturer's recommendations and maintained in a safe operating condition. The examinations for the 3M Versaflo TR-800 PAPRs shall include:
(1) Check the equipment for any physical damage and the integrity of the case;
(2) Remove the battery and inspect for corrosion;
(3) Inspect the contact points to ensure a secure connection to the battery;
(4) Reinsert the battery and power up and shut down to ensure proper connections; and
(5) Check the battery compartment cover or battery attachment to ensure that it is securely fastened.
(6) For equipment utilizing lithium type cells, ensure that lithium cells and/or packs are not damaged or swelled in size. The pre-use examination is limited to inspecting the equipment for indications of physical damage.
(e) The petitioner shall ensure that all 3M Versaflo TR-800 units are serviced according to the manufacturer's recommendations. Dates of service will be recorded in the equipment's logbook and shall include a description of the work performed.
(f) The 3M Versaflo TR-800 units that will be used within 150 feet of pillar workings or longwall faces, or in areas where methane may enter the air current, shall not be put into service until MSHA has initially inspected the equipment and determined that it is in compliance with all the terms and conditions of the Proposed Decision and Order (PDO) granted by MSHA.
(g) Prior to energizing the 3M Versaflo TR-800 inby the last open crosscut, methane tests must be made in accordance with 30 CFR 75.323(a).
(h) All hand-held methane detectors shall be MSHA-approved and maintained in permissible and proper operating condition as defined by 30 CFR 75.320. All methane detectors must provide visual and audible warnings when methane is detected at or above 1.0 percent.
(i) A qualified person as defined in existing 30 CFR 75.151 shall continuously monitor for methane immediately before and during the use of the 3M Versaflo TR-800 PAPR within 150 feet of pillar workings or longwall faces or in areas where methane may enter the air current.
(j) The 3M Versaflo TR-800 PAPR shall not be used if methane is detected in concentrations at or above 1.0 percent methane. When 1.0 percent or more of methane is detected while the Versaflo TR-800 is being used, the equipment shall be de-energized immediately and the equipment withdrawn outby the last open crosscut.
(k) The petitioner will use only 3M TR-830 Battery Pack, which meets lithium battery safety standard UL 1642 or IEC 62133, in the 3M Versaflo TR-800 PAPR.
(l) The battery packs must be “changed out” in intake air outby the last open crosscut. Before each shift when the 3M Versaflo TR-800 is to be used, all batteries and power units for the equipment must be charged sufficiently so that they are not expected to be replaced on that shift.
(m) The following maintenance and use conditions shall apply to equipment containing lithium-type batteries:
(1) Always correctly use and maintain the lithium-ion battery packs. The 3M TR-830 Battery Pack may not be disassembled or modified by anyone other than persons permitted by the manufacturer of the equipment.
(2) The 3M TR-830 Battery Pack must only be charged in an area free of combustible material, readily monitored and located on the surface of the mine. The 3M TR-830 Battery Pack is to be charged by either: ( printed page 16979)
(i) 3M Battery Charger Kit TR-641N, which includes one 3M Charger Cradle TR-640 and one 3M Power Supply TR-941N, or,
(ii) 3M 4-Station Battery Charger Kit TR-644N, which includes four 3M Charger Cradles TR-640 and one 3M 4- Station Battery Charger Base/Power Supply TR-944N.
(3) The batteries must not be allowed to get wet. This does not preclude incidental exposure of sealed battery packs.
(4) The batteries shall not be used, charged or stored in locations where the manufacturer's recommended temperature limits are exceeded. The batteries must not be placed in direct sunlight or used or stored near a source of heat.
(5) The batteries will not be used at the end of their life cycle (i.e., when there is a performance decrease of greater than 20% in battery-operated equipment). The battery will be disposed of properly.
(n) Personnel engaged in the use of the 3M Versaflo TR-800 and shall be properly trained to recognize the hazards and limitations associated with the use of the equipment in areas where methane could be present. Additionally, personnel shall be trained regarding proper procedures for donning Self Contained Self Rescuers (SCSRs) during a mine emergency while wearing the 3M VersaFlow TR-800 or PAPR. The mine operator shall submit proposed revisions to update the Mine Emergency Evacuation and Firefighting Program of Instruction under 30 CFR 75.1502 to address this issue.
(o) Within 60 days after the PDO becomes final, the operator shall submit proposed revisions for its approved 30 CFR part 48 training plans to the Mine Safety and Health Enforcement District Manager. These proposed revisions shall specify initial and refresher training regarding the terms and conditions stated in the PDO. When training is conducted on the terms and conditions in this Order, an MSHA Certificate of Training (Form 5000-23) shall be completed. Comments shall be included on the Certificate of Training indicating that the training received was for use of the 3M Versaflo TR-800.
(p) All personnel who will be involved with or affected by the use of the 3M Versaflo TR-800 PAPR shall receive training in accordance with 30 CFR 48.7 on the requirements of this Order within 60 days of the date the PDO becomes final. Such training must be completed before any 3M Versaflo TR-800 can be used within 150 feet of pillar workings or longwall faces. The operator shall keep a record of such training and provide such record to MSHA upon request.
(q) The operator shall provide annual retraining to all personnel who will be involved with or affected by the use of the 3M Versaflo TR-800 PAPR in accordance with 30 CFR 48.8. The operator shall train new miners on the requirements of the PDO in accordance with 30 CFR 48.5, and shall train experienced miners on the requirements of the PDO in accordance with 30 CFR 48.6. The operator shall keep a record of such training and provide such record to MSHA upon request.
(r) Once approved, the operator shall post the PDO in unobstructed locations on the bulletin boards and/or in other conspicuous places where notices to miners are ordinarily posted.
There are no representatives of miners at Glen Alum Tunnel Mine. A copy of this Petition has been posted on the bulletin board as of January 7, 2026.
The petitioner asserts that the alternative method will guarantee no less than the same measure of protection afforded the miners under the mandatory standard.
Jessica D. Senk,
Acting Director, Office of Standards, Regulations, and Variances.
[FR Doc. 2026-06512 Filed 4-2-26; 8:45 am]
BILLING CODE 4520-43-P
Published Document: 2026-06512 (91 FR 16977)
Named provisions
Related changes
Source
Classification
Who this affects
Taxonomy
Browse Categories
Get Labor & Employment alerts
Weekly digest. AI-summarized, no noise.
Free. Unsubscribe anytime.
Get alerts for this source
We'll email you when FR: Labor Department publishes new changes.