Patent Application for Blood Flow and Shear Stress Calculation

Email

Summary

The USPTO has published a patent application (US20260088181A1) for a method to calculate blood flow and shear stress in aortas with bicuspid aortic valves. The application, filed by the University of Seoul Industry Cooperation Foundation, details a process using characteristic values of the valve to compute these metrics.

What changed

This document is a publication of a patent application filed with the USPTO, not a regulatory rule or guidance. The application (US20260088181A1) describes a method for calculating blood flow and shear stress in aortas, specifically for patients with a bicuspid aortic valve. The method involves receiving specific valve characteristics and using a governing equation in a bipolar coordinate system to compute blood flow per unit area and associated shear stress.

As this is a patent application, it does not impose direct regulatory obligations on entities. However, it signifies potential future technological advancements in cardiovascular monitoring and diagnostics. Companies involved in medical device development, health informatics, or cardiovascular research may find this technology relevant for innovation and intellectual property considerations.

Source document (simplified)

← USPTO Patent Applications

METHOD FOR CALCULATING BLOOD FLOW AND SHEAR STRESS OF AORTA HAVING A BICUSPID AORTIC VALVE, READABLE MEDIUM STORING THE SAME AND MEDICAL DEVICE USING THE SAME

Application US20260088181A1 Kind: A1 Mar 26, 2026

Assignee

University of Seoul Industry Cooperation Foundation

Inventors

Do Yeol AHN

Abstract

Disclosed are a method for calculating blood flow and shear stress of aorta having a bicuspid aortic valve, readable medium storing the method and a medical device using the method. A method for calculating blood flow and shear stress of aorta having a bicuspid aortic valve, which is performed by an electronic device, the method comprises receiving characteristic values of a bicuspid aortic valve, and calculating blood flow per unit area and shear stress applied to the aorta in a bipolar coordinate system of governing equation.

CPC Classifications

G16H 50/30 G06F 17/11

Filing Date

2024-11-04

Application No.

18936705

View original document →

Named provisions

METHOD FOR CALCULATING BLOOD FLOW AND SHEAR STRESS OF AORTA HAVING A BICUSPID AORTIC VALVE, READABLE MEDIUM STORING THE SAME AND MEDICAL DEVICE USING THE SAME

Classification

Agency
USPTO
Instrument
Notice
Legal weight
Non-binding
Stage
Draft
Change scope
Minor
Document ID
US20260088181A1

Who this affects

Applies to
Healthcare providers
Industry sector
3345 Medical Device Manufacturing
Activity scope
Medical Device Development Health Informatics
Geographic scope
United States US

Taxonomy

Primary area
Healthcare
Operational domain
Research & Development
Topics
Medical Devices Data Analysis

Get Healthcare alerts

Weekly digest. AI-summarized, no noise.

Free. Unsubscribe anytime.

Get alerts for this source

We'll email you when ChangeBridge: Patent Apps - Health Informatics (G16H) publishes new changes.

Optional. Personalizes your daily digest.

Free. Unsubscribe anytime.