CISA: Schneider Electric Plant iT/Brewmaxx Vulnerabilities Allow Remote Code Execution

Favicon for www.cisa.gov CISA ICS-CERT Advisories
Published March 24th, 2026
Detected March 24th, 2026
Email

Summary

CISA has issued an advisory regarding multiple vulnerabilities in Schneider Electric's Plant iT/Brewmaxx software, versions 9.60 and above. Successful exploitation could lead to privilege escalation and remote code execution. The advisory provides specific CVE details and mitigation steps recommended by the vendor.

What changed

CISA has released an advisory (ICSA-26-083-03) detailing critical vulnerabilities (CVE-2025-49844, CVE-2025-46817, CVE-2025-46818, CVE-2025-46819) affecting Schneider Electric's Plant iT/Brewmaxx software, versions 9.60 and above. These vulnerabilities, including Use After Free and Integer Overflow, could allow for privilege escalation and remote code execution, posing a significant risk to critical infrastructure sectors such as Energy, Critical Manufacturing, and Commercial Facilities worldwide.

Schneider Electric recommends immediate mitigation by applying patch ProLeiT-2025-001, disabling specific Redis eval commands, and enforcing secure Redis configurations. Additionally, standard cybersecurity best practices for industrial control systems are advised, including network isolation, physical security, and secure remote access. Compliance officers should ensure these patches and configurations are implemented promptly to prevent potential exploitation and maintain operational integrity.

What to do next

  1. Apply patch ProLeiT-2025-001 to affected Schneider Electric Plant iT/Brewmaxx systems.
  2. Disable Redis eval commands on application servers, VisuHub, engineering workstations, and emergency mode workstations.
  3. Implement recommended cybersecurity best practices for industrial control systems, including network isolation and secure remote access.

Source document (simplified)

ICS Advisory

Schneider Electric Plant iT/Brewmaxx

Release Date

March 24, 2026

Alert Code ICSA-26-083-03 Related topics: Industrial Control System Vulnerabilities, Industrial Control Systems View CSAF

Summary

Successful exploitation of these vulnerabilities could risk privilege escalation, which could result in remote code execution.

The following versions of Schneider Electric Plant iT/Brewmaxx are affected:

  • Plant iT/Brewmaxx 9.60andabove (CVE-2025-49844, CVE-2025-46817, CVE-2025-46818, CVE-2025-46819)

| CVSS | Vendor | Equipment | Vulnerabilities |
| --- | --- | --- | --- |
| v3 9.9 | Schneider Electric | Schneider Electric Plant iT/Brewmaxx | Use After Free, Integer Overflow or Wraparound, Improper Control of Generation of Code ('Code Injection') |

Background

  • Critical Infrastructure Sectors: Energy, Critical Manufacturing, Commercial Facilities
  • Countries/Areas Deployed: Worldwide
  • Company Headquarters Location: France

Vulnerabilities

Expand All +

CVE-2025-49844

The affected product uses Redis, an open-source, in-memory database. Versions 8.2.1 and below allow an authenticated user to use a specially crafted Lua script to manipulate the garbage collector, trigger a use-after-free, and potentially lead to remote code execution.

View CVE Details

Affected Products

Schneider Electric Plant iT/Brewmaxx

Vendor:
Schneider Electric Product Version:
Schneider Electric Plant iT/Brewmaxx: 9.60andabove Product Status:
known_affected

Remediations

Mitigation
Schneider Electric recommends users immediately apply the following mitigations to reduce the risk of exploit:

Mitigation
Install Patch ProLeiT-2025-001 via ProLeiT Support
https://www.proleit.com/support/

Mitigation
After installing ProLeiT-2025-001, disable the eval commands in Redis on the application server, VisuHub, engineering workstations, and workstations with emergency mode functionality

Mitigation
Force usage of secure Redis configuration templates in system settings as documented in the patch manual

Mitigation
Restart all patched servers and workstations

Mitigation
Schneider Electric strongly recommends the following industry cybersecurity best practices.

Mitigation
Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.

Mitigation
Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.

Mitigation
Place all controllers in locked cabinets and never leave them in the "Program" mode.

Mitigation
Never connect programming software to any network other than the network intended for that device.

Mitigation
Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.

Mitigation
Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.

Mitigation
Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.

Mitigation
When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.

Mitigation
For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.
https://www.se.com/us/en/download/document/7EN52-0390/

Vendor fix
For more information, see Schneider Electric security notification "SEVD-2026-013-01 Multiple Third-Party Vulnerabilities on ProLeiT Plant iT/Brewmaxx"
https://download.schneider-electric.com/files?pDocRef=SEVD-2026-013-01&penDocType=Security+and+Safety+Notice&pFile_Name=SEVD-2026-013-01.pdf

Relevant CWE: CWE-416 Use After Free

Metrics

| CVSS Version | Base Score | Base Severity | Vector String |
| --- | --- | --- | --- |
| 3.1 | 9.9 | CRITICAL | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H |

CVE-2025-46817

The affected product uses Redis, an open-source, in-memory database. Versions 8.2.1 and below allow an authenticated user to use a specially crafted Lua script to cause an integer overflow and potentially lead to remote code execution

View CVE Details

Affected Products

Schneider Electric Plant iT/Brewmaxx

Vendor:
Schneider Electric Product Version:
Schneider Electric Plant iT/Brewmaxx: 9.60andabove Product Status:
known_affected

Remediations

Mitigation
Schneider Electric recommends users immediately apply the following mitigations to reduce the risk of exploit:

Mitigation
Install Patch ProLeiT-2025-001 via ProLeiT Support
https://www.proleit.com/support/

Mitigation
After installing ProLeiT-2025-001, disable the eval commands in Redis on the application server, VisuHub, engineering workstations, and workstations with emergency mode functionality

Mitigation
Force usage of secure Redis configuration templates in system settings as documented in the patch manual

Mitigation
Restart all patched servers and workstations

Mitigation
Schneider Electric strongly recommends the following industry cybersecurity best practices.

Mitigation
Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.

Mitigation
Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.

Mitigation
Place all controllers in locked cabinets and never leave them in the "Program" mode.

Mitigation
Never connect programming software to any network other than the network intended for that device.

Mitigation
Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.

Mitigation
Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.

Mitigation
Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.

Mitigation
When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.

Mitigation
For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.
https://www.se.com/us/en/download/document/7EN52-0390/

Vendor fix
For more information, see Schneider Electric security notification "SEVD-2026-013-01 Multiple Third-Party Vulnerabilities on ProLeiT Plant iT/Brewmaxx"
https://download.schneider-electric.com/files?pDocRef=SEVD-2026-013-01&penDocType=Security+and+Safety+Notice&pFile_Name=SEVD-2026-013-01.pdf

Relevant CWE: CWE-190 Integer Overflow or Wraparound

Metrics

| CVSS Version | Base Score | Base Severity | Vector String |
| --- | --- | --- | --- |
| 3.1 | 7 | HIGH | CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H |

CVE-2025-46818

The affected product uses Redis, an open-source, in-memory database. Versions 8.2.1 and below allow an authenticated user to use a specially crafted Lua script to manipulate different LUA objects and potentially run their own code in the context of another user.

View CVE Details

Affected Products

Schneider Electric Plant iT/Brewmaxx

Vendor:
Schneider Electric Product Version:
Schneider Electric Plant iT/Brewmaxx: 9.60andabove Product Status:
known_affected

Remediations

Mitigation
Schneider Electric recommends users immediately apply the following mitigations to reduce the risk of exploit:

Mitigation
Install Patch ProLeiT-2025-001 via ProLeiT Support
https://www.proleit.com/support/

Mitigation
After installing ProLeiT-2025-001, disable the eval commands in Redis on the application server, VisuHub, engineering workstations, and workstations with emergency mode functionality

Mitigation
Force usage of secure Redis configuration templates in system settings as documented in the patch manual

Mitigation
Restart all patched servers and workstations

Mitigation
Schneider Electric strongly recommends the following industry cybersecurity best practices.

Mitigation
Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.

Mitigation
Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.

Mitigation
Place all controllers in locked cabinets and never leave them in the "Program" mode.

Mitigation
Never connect programming software to any network other than the network intended for that device.

Mitigation
Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.

Mitigation
Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.

Mitigation
Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.

Mitigation
When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.

Mitigation
For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.
https://www.se.com/us/en/download/document/7EN52-0390/

Vendor fix
For more information, see Schneider Electric security notification "SEVD-2026-013-01 Multiple Third-Party Vulnerabilities on ProLeiT Plant iT/Brewmaxx"
https://download.schneider-electric.com/files?pDocRef=SEVD-2026-013-01&penDocType=Security+and+Safety+Notice&pFile_Name=SEVD-2026-013-01.pdf

Relevant CWE: CWE-94 Improper Control of Generation of Code ('Code Injection')

Metrics

| CVSS Version | Base Score | Base Severity | Vector String |
| --- | --- | --- | --- |
| 3.1 | 6 | MEDIUM | CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:N |

CVE-2025-46819

The affected product uses Redis, an open-source, in-memory database. Versions 8.2.1 and below allow an authenticated user to use a specially crafted LUA script to read out-of-bound data or crash the server and subsequent denial of service.

View CVE Details

Affected Products

Schneider Electric Plant iT/Brewmaxx

Vendor:
Schneider Electric Product Version:
Schneider Electric Plant iT/Brewmaxx: 9.60andabove Product Status:
known_affected

Remediations

Mitigation
Schneider Electric recommends users immediately apply the following mitigations to reduce the risk of exploit:

Mitigation
Install Patch ProLeiT-2025-001 via ProLeiT Support
https://www.proleit.com/support/

Mitigation
After installing ProLeiT-2025-001, disable the eval commands in Redis on the application server, VisuHub, engineering workstations, and workstations with emergency mode functionality

Mitigation
Force usage of secure Redis configuration templates in system settings as documented in the patch manual

Mitigation
Restart all patched servers and workstations

Mitigation
Schneider Electric strongly recommends the following industry cybersecurity best practices.

Mitigation
Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.

Mitigation
Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.

Mitigation
Place all controllers in locked cabinets and never leave them in the "Program" mode.

Mitigation
Never connect programming software to any network other than the network intended for that device.

Mitigation
Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.

Mitigation
Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.

Mitigation
Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.

Mitigation
When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.

Mitigation
For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.
https://www.se.com/us/en/download/document/7EN52-0390/

Vendor fix
For more information, see Schneider Electric security notification "SEVD-2026-013-01 Multiple Third-Party Vulnerabilities on ProLeiT Plant iT/Brewmaxx"
https://download.schneider-electric.com/files?pDocRef=SEVD-2026-013-01&penDocType=Security+and+Safety+Notice&pFile_Name=SEVD-2026-013-01.pdf

Relevant CWE: CWE-190 Integer Overflow or Wraparound

Metrics

| CVSS Version | Base Score | Base Severity | Vector String |
| --- | --- | --- | --- |
| 3.1 | 6.3 | MEDIUM | CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:H |

Acknowledgments

  • Schneider Electric reported these vulnerabilities to CISA

Legal Notice and Terms of Use

This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy).

Recommended Practices

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.

Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet.

Locate control system networks and remote devices behind firewalls and isolating them from business networks.

When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

Do not click web links or open attachments in unsolicited email messages.

Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.

Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

Revision History

  • Initial Release Date: 2026-03-24

| Date | Revision | Summary |
| --- | --- | --- |
| 2026-03-24 | 1 | Initial Republication of SEVD-2026-013-01 |

Legal Notice and Terms of Use

This product is provided subject to this Notification and this Privacy & Use policy.

Vendor

  • Schneider Electric

Tags

Sector: Commercial Facilities Sector, Critical Manufacturing Sector, Energy Sector Topics: Industrial Control System Vulnerabilities, Industrial Control Systems

Please share your thoughts

We recently updated our anonymous product survey; we welcome your feedback.

Related Advisories

Mar 24, 2026

ICS Advisory | ICSA-26-083-01

Pharos Controls Mosaic Show Controller

Mar 24, 2026

ICS Advisory | ICSA-26-083-02

Schneider Electric EcoStruxure Foxboro DCS

Mar 19, 2026

ICS Advisory | ICSA-26-078-04

Schneider Electric EcoStruxure PME and EPO

Mar 19, 2026

ICS Advisory | ICSA-26-078-01

Schneider Electric Modicon M241, M251, and M262

Named provisions

Summary Background Vulnerabilities

Source

Analysis generated by AI. Source diff and links are from the original.

Classification

Agency
CISA
Published
March 24th, 2026
Instrument
Notice
Legal weight
Non-binding
Stage
Final
Change scope
Substantive
Document ID
ICSA-26-083-03

Who this affects

Applies to
Energy companies Manufacturers Technology companies
Industry sector
2111 Oil & Gas Extraction 2361 Construction 3254 Pharmaceutical Manufacturing 3345 Medical Device Manufacturing 6221 Hospitals & Health Systems 9211 Government & Public Administration
Activity scope
Vulnerability Management Industrial Control System Security
Geographic scope
United States US

Taxonomy

Primary area
Cybersecurity
Operational domain
IT Security
Compliance frameworks
NIST CSF
Topics
Industrial Control Systems Vulnerability Management

Get Data Privacy & Cybersecurity alerts

Weekly digest. AI-summarized, no noise.

Free. Unsubscribe anytime.

Get alerts for this source

We'll email you when CISA ICS-CERT Advisories publishes new changes.

Free. Unsubscribe anytime.