Changeflow GovPing Data Privacy & Cybersecurity CISA ICS Advisory: Schneider Electric Modicon V...
Priority review Notice Added Final

CISA ICS Advisory: Schneider Electric Modicon Vulnerabilities

Favicon for www.cisa.gov CISA ICS-CERT Advisories
Published March 19th, 2026
Detected March 19th, 2026
Email

Summary

CISA issued an advisory regarding vulnerabilities in Schneider Electric Modicon M241, M251, and M262 controllers. Successful exploitation could lead to a denial-of-service condition. Affected versions are prior to 5.4.13.12 for M241/M251 and 5.4.10.12 for M262.

What changed

CISA has released an advisory (ICSA-26-078-01) detailing vulnerabilities in Schneider Electric Modicon M241, M251, and M262 industrial control systems. The identified vulnerability, CVE-2025-13901, is a CWE-404 Improper Resource Shutdown or Release that could allow an unauthenticated attacker to cause a partial denial-of-service by occupying active communication channels with a malicious payload. Affected versions include Modicon M241 and M251 prior to 5.4.13.12, and Modicon M262 prior to 5.4.10.12.

Schneider Electric has released firmware version 5.4.13.12 for Modicon M241 (delivered with EcoStruxure™ Machine Expert v2.5.0.1) as a fix for this vulnerability. Users are advised to update their firmware and reboot their controllers. While the advisory notes that the vulnerability is deployed worldwide across critical infrastructure sectors such as Commercial Facilities, Critical Manufacturing, and Energy, it does not specify a compliance deadline or penalties for non-compliance, but emphasizes the risk of service disruption.

What to do next

  1. Update Schneider Electric Modicon M241, M251, and M262 controllers to the latest firmware versions (5.4.13.12 for M241/M251, 5.4.10.12 for M262).
  2. Reboot affected controllers after firmware update.
  3. Review Schneider Electric's mitigation guidance for specific workarounds.

Source document (simplified)

ICS Advisory

Schneider Electric Modicon M241, M251, and M262

Release Date

March 19, 2026

Alert Code ICSA-26-078-01 Related topics: Industrial Control System Vulnerabilities, Industrial Control Systems View CSAF

Summary

Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition on the product.

The following versions of Schneider Electric Modicon M241, M251, and M262 are affected:

  • Modicon M241 versions prior to 5.4.13.12 ModiconControllerM241
  • Modicon M251 versions prior to 5.4.13.12 ModiconControllerM251
  • Modicon M262 versions prior to 5.4.10.12 ModiconControllerM262

| CVSS | Vendor | Equipment | Vulnerabilities |
| --- | --- | --- | --- |
| v3 5.3 | Schneider Electric | Schneider Electric Modicon M241, M251, and M262 | Improper Resource Shutdown or Release |

Background

  • Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Energy
  • Countries/Areas Deployed: Worldwide
  • Company Headquarters Location: France

Vulnerabilities

Expand All +

CVE-2025-13901

CWE-404 Improper Resource Shutdown or Release vulnerability exists that could cause partial Denial of Service on Machine Expert protocol when an unauthenticated attacker sends malicious payload to occupy active communication channels.

View CVE Details

Affected Products

Schneider Electric Modicon M241, M251, and M262

Vendor:
Schneider Electric Product Version:
Schneider Electric Modicon M241 versions prior to 5.4.13.12: ModiconControllerM241, Schneider Electric Modicon M251 versions prior to 5.4.13.12: ModiconControllerM251, Schneider Electric Modicon M262 versions prior to 5.4.10.12: ModiconControllerM262 Product Status:
known_affected

Remediations

Mitigation
Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Modicon Controller M241 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M241 to the latest Firmware and perform reboot. For instructions refer to Modicon M241 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/.
https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/

Mitigation
Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Modicon Controller M241 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M241 to the latest Firmware and perform reboot. For instructions refer to Modicon M241 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/.
https://www.se.com/ww/en/download/document/EIO0000005500/

Mitigation
Modicon Controller M251 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M251 to the latest Firmware and perform reboot. For instructions refer to Modicon M251 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/.
https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/

Mitigation
Modicon Controller M251 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M251 to the latest Firmware and perform reboot. For instructions refer to Modicon M251 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/.
https://www.se.com/ww/en/download/document/EIO0000005500/

Mitigation
Modicon Controller M262 Firmware version 5.4.10.12 delivered with EcoStruxure™ Machine Expert v2.5 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M262 to the latest Firmware and perform reboot. For instructions refer to Modicon M262 Logic/Motion Controller, Programming Guide: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/.
https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/

Mitigation
Modicon Controller M262 Firmware version 5.4.10.12 delivered with EcoStruxure™ Machine Expert v2.5 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M262 to the latest Firmware and perform reboot. For instructions refer to Modicon M262 Logic/Motion Controller, Programming Guide: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/.
https://www.se.com/ww/en/download/document/EIO0000005500/

Mitigation
For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-069-01 Improper Resource Shutdown or Release vulnerability in Multiple Products - SEVD-2026-069-01 PDF Version: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-069-01.pdf. Improper Resource Shutdown or Release vulnerability in Multiple Products - SEVD-2026-069-01 CSAF Version: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-069-01.json.
https://download.schneider-electric.com/files?pDocRef=SEVD-2026-069-01&penDocType=Security+and+Safety+Notice&pFile_Name=SEVD-2026-069-01.pdf

Mitigation
All affected products: If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from public internet or untrusted networks. Filter ports and IP through the embedded firewall. Use encrypted communication links. Use VPN (Virtual Private Networks) tunnels if remote access is required. The "Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment" provide product specific hardening guidelines: https://download.schneider-electric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242.
https://download.schneider-electric.com/files?penDocType=User+guide&pFileName=EIO0000004242.00.pdf&pDoc_Ref=EIO0000004242

Relevant CWE: CWE-404 Improper Resource Shutdown or Release

Metrics

| CVSS Version | Base Score | Base Severity | Vector String |
| --- | --- | --- | --- |
| 3.1 | 5.3 | MEDIUM | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L |

Acknowledgments

  • Noam Moshe of Claroty reported this vulnerability to Schneider Electric
  • Schneider Electric reported this vulnerability to CISA

Legal Notice and Terms of Use

This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy).

Recommended Practices

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.

Locate control system networks and remote devices behind firewalls and isolating them from business networks.

When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

Do not click web links or open attachments in unsolicited email messages.

Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.

Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.

Revision History

  • Initial Release Date: 2026-03-19

| Date | Revision | Summary |
| --- | --- | --- |
| 2026-03-19 | 1 | Initial Republication of Schneider Electric CPCERT SEVD-2026-069-01 |

Legal Notice and Terms of Use

This product is provided subject to this Notification and this Privacy & Use policy.

Vendor

  • Schneider Electric

Tags

Sector: Commercial Facilities Sector, Critical Manufacturing Sector, Energy Sector Topics: Industrial Control System Vulnerabilities, Industrial Control Systems

Please share your thoughts

We recently updated our anonymous product survey; we welcome your feedback.

Related Advisories

Mar 19, 2026

ICS Advisory | ICSA-26-078-08

Automated Logic WebCTRL Premium Server

Mar 19, 2026

ICS Advisory | ICSA-26-078-05

Mitsubishi Electric CNC Series

Mar 19, 2026

ICS Advisory | ICSA-26-078-02

Schneider Electric Modicon Controllers M241, M251, M258, and LMC058

Mar 19, 2026

ICS Advisory | ICSA-26-078-03

Schneider Electric EcoStruxure Automation Expert

Named provisions

Summary Background Vulnerabilities Affected Products Remediations

Source

Analysis generated by AI. Source diff and links are from the original.

Classification

Agency
CISA
Published
March 19th, 2026
Instrument
Notice
Legal weight
Non-binding
Stage
Final
Change scope
Substantive
Document ID
ICSA-26-078-01

Who this affects

Applies to
Manufacturers Energy companies Commercial Facilities
Industry sector
3345 Medical Device Manufacturing 2210 Electric Utilities 3114 Food & Beverage Manufacturing
Activity scope
Industrial Control System Management Denial-of-Service Prevention
Geographic scope
United States US

Taxonomy

Primary area
Cybersecurity
Operational domain
IT Security
Topics
Industrial Control Systems Vulnerability Management

Get Data Privacy & Cybersecurity alerts

Weekly digest. AI-summarized, no noise.

Free. Unsubscribe anytime.

Get alerts for this source

We'll email you when CISA ICS-CERT Advisories publishes new changes.

Free. Unsubscribe anytime.